Western Telematic MT5634 Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Sítě Western Telematic MT5634. Western Telematic MT5634 User`s guide [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
RPS-10 Series
Expandable Remote AC Power Switches
Models Covered:
RPS-10 Standard Unit
RPS-10 HD Heavy Duty Unit
RPS-10 EC 220/230 VAC Unit
User's Guide
5 Sterling · Irvine · California 92618
(949) 586-9950
· Toll Free: 1-800-854-7226
Fax: (949) 583-9514
· http://www.wti.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 16 17

Shrnutí obsahu

Strany 1 - RPS-10 Series

RPS-10 SeriesExpandable Remote AC Power SwitchesModels Covered:RPS-10 Standard UnitRPS-10 HD Heavy Duty UnitRPS-10 EC 220/230 VAC UnitUser's Guid

Strany 2 - Table of Contents

3.6. Test for Proper InstallationAfter installation, the following test should be performed to make certain all modules areoperating correctly.1. Esta

Strany 3 - 1. Introduction

4. OperationEach RPS-10 module can be switched or toggled by an ASCII command string sent to theMaster Module control port. The Control Device must se

Strany 4 - 2. Unit Description

Examples:To toggle the Switched AC Outlet on the RPS-10 Module at Address "3", send the followingcommand:^B^X^X^B^X^X3T^MTo set the Switched

Strany 5 - 2.2.2. RPS-10 EC Back Panel

4.1. Optional Accessories4.1.1. Three Module RackWTI offers an optional three module rack, which fits most standard instrument racks. Toassemble the r

Strany 6 - 3. Installation

4.1.2. Snap AdaptersWTI offers a complete selection of snap adapters and cables designed to simplify connectionbetween the RPS-10M Master Module and y

Strany 7 - 3.2. Set-Up Switches

4.2. Cable Wiring DiagramsPage 13RPS-10 Series Remote Power Switches, User's Guide OperationFigure 8: Cable Wiring Diagram; RPS-10 to ModemFigure

Strany 8 - 3.3. Linking Modules

A. SpecificationsSwitched Outlet / Terminal Block:RPS-10: 1 Plug, Rated at 115 VAC @ 10 Amps Max.RPS-10 HD: 1 Plug, Rated at 115 VAC @ 15 Amps Max.RPS

Strany 9 - 3.5. Power Connection

B. FCC Statement:This device complies with part 15 of the FCC Rules. Operation is subject to the following twoconditions:1. This device may not cause

Strany 10

Table of Contents1. Introduction...12. Unit Description...22.1. Fr

Strany 11 - 4. Operation

1. IntroductionNetwork equipment sometimes "locks-up", making it impossible to communicate. In the past,this situation required a trip to th

Strany 12

2. Unit Description2.1. Front PanelÀAC ON: Lights when power to the Switched Outlet is ON.Á LINK: Flashes when command data is received. RDY: Lights

Strany 13 - 4.1. Optional Accessories

2.2.2. RPS-10 EC Back Panel2.3. Back Panel ComponentsÀSwitched Outlet: (RPS-10, RPS-10 HD, and RPS-10 EC) For connection to your ACpowered device (see

Strany 14 - 4.1.2. Snap Adapters

3. InstallationThe installation procedure consists of the steps listed below. For more information, pleaserefer to the section(s) indicated.1. Set the

Strany 15 - 4.2. Cable Wiring Diagrams

3.2. Set-Up SwitchesPrior to connecting AC power to the RPS-10 Modules, configure the Set-Up Switches on eachmodule according to the requirements of y

Strany 16 - A. Specifications

3.3. Linking ModulesConnect straight wired RJ11 cables between the Link Ports to link the RPS-10 Master Moduleand Satellite Modules as shown in Figure

Strany 17 - C. Customer Service

3.4. Control Port ConnectionThe RS232 Control Port is a male, DB9 connector, used for connection to a PC or externalmodem. The Control Port employs a

Komentáře k této Příručce

Žádné komentáře